| Tham số | Giá trị |
|---|---|
| Mục | Specifications |
| PFHD | 1.66 × 10-10(Note:Probability of dangerous failure per hour) |
| MTTFD | 100 years or more(Note:Mean time to dangerous failure (in years)) |
| Cân nặng | Net weight: 250 g approx. |
| Chi tiết | Applicantion expansion unit for the SF4B series |
| Sản phẩm | Exclusive Control Unit for Safety Light Curtain |
| Vật liệu | Enclosure: ABS |
| Mã số linh kiện | SF-C14EX |
| Tên sản phẩm | Exclusive Control Unit for Safety Light Curtain SF-C10 |
| Điện áp nguồn | 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Mã sản phẩm | SF-C14EX |
| Độ ẩm môi trường | 30 to 85 % RH, Storage: 30 to 95 % RH |
| Danh mục kiểm soát | ISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards |
| Khả năng chống sốc | 30 G acceleration in X, Y and Z directions three times each |
| Tắt tiếng đầu ra đèn | Applicable muting lamp: 24 V DC, 3.6 to 30 W (L1, L2 of each unit) |
| Nhiệt độ môi trường xung quanh | -10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158 ℉ |
| Đầu nối | Detachable spring-cage terminal |
| Mức tiêu thụ hiện tại | 0.2 A or less (Excluding Safety light curtain and other external connecting device) |
| Khả năng chống rung | 10 to 55 Hz frequency, 0.35 mm0.014 indouble amplitude in X, Y and Z directions for two hours each |
| Điện trở cách điện | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Tiêu chuẩn áp dụng: Nhật Bản | JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4, PLe) |
| Tuân thủ chỉ thị đánh dấu CE | Machinery Directive, EMC Directive, RoHS Directive |
| Tiêu chuẩn áp dụng: Châu Âu (EU) | EN 55011, EN ISO 13849-1 (Category 4, PLe) |
| Màn chắn ánh sáng an toàn có thể kết nối | SF4B / SF4B-Gseries(Note:The handy-controllerSFB-HC(optional) cannot be used withSF-C14EX-01.) |
| Tiêu chuẩn áp dụng: Bắc Mỹ | ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) |
| Tắt tiếng đầu ra đèn: Mạch bảo vệ | Incorporated |
| Tiêu chuẩn áp dụng: Tiêu chuẩn quốc tế | IEC 61496-1 (Type 4), IEC 61496 (Type 4),ISO 13849-1 (Category 4, PLe) |
| Khả năng chống chịu môi trường: Mức độ bảo vệ | Enclosure: IP40Terminal: IP20 |
| Khả năng chống chịu môi trường: Điện áp cường độ điện môi | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Các đầu ra an toàn (Đầu ra an toàn 1, Đầu ra an toàn 2, Đầu ra an toàn 3) | PNP open-collector transistor 2 outputs × 3 or NPN open-collector transistor 2 outputs × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 200 mA・Applied voltage: same as supply voltage(between the safety output and +V)・Residual voltage: 2 V or less (at 200 mA source current)<When NPN output is selected>・Maximum sink current: 200 mA・Applied voltage: same as supply voltage(between the safety output and 0 V)・Residual voltage: 2 V or less (at 200 mA sink current) |
| Các đầu ra an toàn (Đầu ra an toàn 1, Đầu ra an toàn 2, Đầu ra an toàn 3): Thời gian phản hồi | OFF response: 14 ms or less (Safety output 1 and 2: including the response time of the Safety light curtain)ON response: 90 ms or less (auto-reset) / 140 ms or less (manual reset) (Note)(Note) The auto-reset cannot be used with safety output 3. |
| Các đầu ra phụ (Đầu ra phụ 1, Đầu ra phụ 2, Đầu ra phụ 3, Đầu ra phụ 4) | PNP open-collector transistor × 3 or NPN open-collector transistor × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and +V)・Residual voltage: 2 V or less (at 60 mA source current)<When NPN output is selected>・Maximum sink current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and 0 V)・Residual voltage: 2 V or less (at 60 mA sink current) |
| Các đầu ra an toàn (Đầu ra an toàn 1, Đầu ra an toàn 2, Đầu ra an toàn 3): Chế độ hoạt động (Hoạt động đầu ra) | Safety output 1: ON when the safety light curtain is in light receiving condition, OFF when the safety light curtain is in light interrupted condition (Note 3)Safety output 2: ON when the safety light curtain is in light receiving condition or the muting function is validOFF when the safety light curtain is in light interrupted condition and the muting function is invalid (Note 3)Safety output 3: ON when the emergency stop is invalid, OFF when the emergency stop is valid |
| Ngõ ra an toàn (Ngõ ra an toàn 1, Ngõ ra an toàn 2, Ngõ ra an toàn 3): Mạch bảo vệ (Bảo vệ ngắn mạch) | Incorporated |
| Các đầu ra phụ (Đầu ra phụ 1, Đầu ra phụ 2, Đầu ra phụ 3, Đầu ra phụ 4): Chế độ hoạt động (Hoạt động đầu ra) | Auxiliary output 1: ON when the muting function is invalid, OFF when the muting function is validAuxiliary output 2: ON when the override function is invalid, OFF when the override function is validAuxiliary output 3: ON when the muting lamp is normal, OFF when the muting lamp is errorAuxiliary output 4: ON when the light curtain is in light interrupted condition, OFF when the light curtain is in light receiving condition(Note:The auxiliary output incorporated in theSF4Bseries is output.) |
| Các đầu ra phụ (Đầu ra phụ 1, Đầu ra phụ 2, Đầu ra phụ 3, Đầu ra phụ 4): Mạch bảo vệ (Bảo vệ ngắn mạch) | Incorporated |
Thông số kỹ thuật và dữ liệu hiệu năng
Hướng dẫn cài đặt và vận hành