| Tham số | Giá trị |
|---|---|
| Note regarding axial connection technology:Only for stranded wires. The conductor cross sections stated refer to the geometric cross section of the cable used.Use of cables with a geometric cross section very different from that of the cable's nominal cross section should be checked before use.The wiring space of the axial screw method is designed for fine strand cables according to VDE 0295 class 5. Deviating cable structures (e.g. class 6 cables) should be checked before use.ConnectionBefore starting to connect, ensure that the tapered screw is turned back all the way (chamber is open). The cables must not be twisted. The cores should be slid to the limit stop in the contact chamber (until insulation touches contact). Hold cores in position and use socket wrench to tighten. The used core end should be cut off before connecting again. The connection screw may only be retightened once to prevent the strands from breaking. To prevent damage to the contact, the core / cable should be mechanically intercepted at an appropriate distance from the connection point (e.g. by using a plate cutout). DIN VDE 0100-520:2003-06 contains information on how to do this correctly. | |
| Chiều rộng | 34.2 mm |
| Chiều cao | 40.6 mm |
| Chiều dài | 14.6 mm |
| Loạt | HC-M-02 |
| Tổng quan | For HEAVYCON housing type B6 to B48, HC-M-MHR... hinged retaining frame required |
| Ứng dụng | Power |
| Loại sản phẩm | Modular contact insert |
| Ghi chú lắp ráp | - Connection of the wires using a 2 mm Allen wrench.- Housing height ≥ 52 mm.- Axial screw connection only for flexible wires.- Plug-in connections may only be operated only when there is no load/voltage. |
| Dòng điện định mức | 40 A |
| Thông tin liên hệ | Copper alloy |
| Ổ cắm hình lục giác | SW 2 |
| Số điện thoại liên hệ | 1 - 2 |
| Mô-men xoắn siết chặt | 1.5 Nm (2.5 mm² ... 4 mm²) |
| Hồ sơ kết nối | 2 |
| Mức độ ô nhiễm | 3 |
| Bản vẽ kích thước | |
| Số lượng vị trí | 2 |
| Điện áp đột biến định mức | 8 kV |
| Loại quá áp | III |
| Công nghệ kết nối | Axial screw connection |
| Điện áp định mức (III/3) | 1000 V |
| Số lượng khe cắm mô-đun | 1 |
| Tiết diện dây dẫn | 2.5 mm² ... 8 mm² (The cross section specification refers to the geometric cross section of the cable used) |
| Vật liệu mang tiếp xúc | PC |
| Vật liệu bề mặt tiếp xúc | Ag |
| Chu kỳ chèn/rút | ≥ 500 |
| Tiết diện kết nối AWG | 12 ... 10 |
| Nhiệt độ môi trường (khi hoạt động) | -40 °C ... 125 °C |
| Kết nối theo tiêu chuẩn | IEC / EN |
| Xếp hạng khả năng bắt lửa theo tiêu chuẩn UL 94 | V0 |
| Chiều dài của từng sợi dây dẫn được tước vỏ. | 8 mm +1 mm (for 6 mm²) |
Thông số kỹ thuật và dữ liệu hiệu năng